If a machine has a touchy cover interlock giving false 'Close Door or Insert Cartridge Messages', don't try bending the switch's actuating lever to 'adjust' it -- that's asking for trouble. Instead, 'bulk up' the switch's lever with 1/8" diameter heat-shrink tubing. Three 5/16" lengths of Alpha FIT-221 tubing are ideal. It should look like this when you're done installing the tubing lengths.
![](https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgU1hrO9eUZ46VZ20BOCkktMYgfTJXhyH7DoravGNJc1UILgYKGtqKA-aNb6qusWAFhEa52ncHRNxNVb40QEh1yy2CNo7O1RSv3KMq1dk7Mpd-mrO8Yrq5cjIw2it1bsw0sc_OCr-wQIyjE/s400/DSC00266.JPG)
The third tubing length can just barely be gotten slipped on. Make sure you've fully shrunk the first two tubing lengths, and the third length will go on.
# # #
# # #