Fujitsu DL6400/6600 -- Fan Replacement

The following is for replacement of the main fan that's in the right side vertical chassis member. DL6600s have an additional fan for cooling the power supply. Access to it is gained the same way.

- - -

1) Access Cover

2) Control Panel
> Three downward-gripping claws at its upper rear.
> One cable connection.

3) Top Cover
> Two M4x10mm bright pan head screws w/captive washers at the back.
> Tip the cover up at the rear and pull it away. MIND THE CONTROL PANEL CABLE as you do this.

4) Mechanism Tilted Up
> The mechanism is not fastened at the rear. It can be tipped up and propped in position for access to the fan. There should be a prop rod held by two clips at the right side of the chassis pan.
The prop anchor hole is at the rear, just left of the Interface PCA. If the rod is missing, use a suitable screwdriver for a prop.

5) Fan
> Cable connection 'CNFAN'.
> Two M3x30mm YZD pan head screws w/captive washers.
> Air flow direction is outward.

# # #