Friday, January 28, 2011

HP CLJ 2600n Fuser Access

1) Paper Tray

2) Right Side Cover
> One M3x8mm washerhead screw at lower rear.
> Tug the cover away at the lower rear and it will pop free.

3) Left Side Lower Cover (Handgrip Portion of Cover)
> One M3x8mm washerhead screw in handgrip well.
> One claw in front; two claws at underside. Pry the cover away.

4) Left Side Upper Cover
> Pry at the rear edge to free it.

5) Top Cover Grey Inset
> There are two arrowhead marks at the rear. Pry there to free the inset.

6) Top Cover
> Four M3x8mm washerhead screws.
> One flat cable connection.
> Lift the cover away.

7) Face-Down Delivery Platform
> Pry at the rear edge to free it.

8) Cable/Wire Connections
> Cable connection at fuser motor.
> Cable connection at J204.
> Power cable connection at J203. Free the cable from its restraints. The ty-wrapped restraint can be pried up out of the PCA.
> Two sensor cable connections at the left side. CAUTION -- it's easy to dislodge the sensors when disconnecting their cables.
> One red wire terminal at the left side.

9) Fuser
> Two M3x8mm washerhead screws at the fuser's rear -- they're marked by arrowheads.
> One M3x8mm washerhead screw at the right lower rear of the fuser.

# # #

No comments: